Frequently Asked Questions (FAQ)
Q1: What sensing principle does the PR6424/010-131 use?
A1: It uses eddy-current induction to convert displacement into a proportional AC voltage.
Q2: What connector is included with CON031?
A2: A rugged M12 8-pin male connector for secure, quick-disconnect field wiring.
Q3: What gap range provides best linearity?
A3: Operating gaps of 0.5–2 mm deliver optimal ±1 % full-scale linearity.
Q4: Can the cable length be changed?
A4: Yes, custom cable assemblies are available up to 10 m on request.
Q5: How does it handle electromagnetic noise?
A5: Braided cable shielding and integrated grounding reduce EMI/RFI interference.
Q6: What temperature extremes can it endure?
A6: It operates reliably from –40 °C to +125 °C without performance degradation.
Q7: Is periodic calibration required?
A7: Factory calibration is stable; periodic verification depends on application criticality.
Q8: Can I use this sensor for high-speed vibration analysis?
A8: Yes, the 12 kHz bandwidth captures high-frequency vibration components effectively.
Q9: What materials are in contact with the target?
A9: The probe tip and housing are 316 stainless steel for corrosion resistance.
Q10: Where can I obtain technical documentation?
A10: Detailed datasheets, installation guides, and application notes are available from Epro’s support portal.
Related Products
Copyright @ 2026 Automations
XML|Links:
No:77501