• Honeywell 8C-TDOBA1 Digital Output IOTA Module
  • Honeywell 8C-TDOBA1 Digital Output IOTA Module
  • Honeywell 8C-TDOBA1 Digital Output IOTA Module
  • Honeywell 8C-TDOBA1 Digital Output IOTA Module
1. Product Introduction & Overview The 8C‑TDOBA1 is a digital output I/O module (often called DO IOM / DO IOTA / DO termination assembly) in the Series 8 (S8) family. It is designed for use in distr……
Honeywell 8C-TDOBA1 Digital Output IOTA Module
  • Honeywell
  • 8C-TDOBA1
  • Digital Output IOTA Module
  • USA
  • 221 mm × 121 mm × 63 mm
  • 0.35kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 90

Our advantage

Honeywell 8C-TDOBA1 Digital Output IOTA Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 8C-TDOBA1 Digital Output IOTA Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 8C-TDOBA1 Digital Output IOTA Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 8C-TDOBA1 Digital Output IOTA Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


7. FAQ (10 Questions & Answers, QA Format)

Q1: What is the primary purpose of the 8C‑TDOBA1 module?
A1: It provides discrete (on/off) outputs under control from the logic system to drive actuators, relays, valves, etc.

Q2: How many output channels does 8C‑TDOBA1 support?
A2: It supports 32 discrete output channels.

Q3: What is the typical output voltage and current rating per channel?
A3: The output is 24 V DC (typical) with a per-channel load current limit of around 100 mA.

Q4: Does it support safe or fault state behavior?
A4: Yes—each channel can be configured to hold its last state or be forced to a safe state (e.g. off) when a fault occurs.

Q5: Can it isolate field and system power?
A5: Yes. If an external 24 V field supply is used, the module can provide galvanic isolation between system and field sides.

Q6: What is its typical turn-on / turn-off time?
A6: The switching (on/off) response is up to 10 ms in the worst case.

Q7: What environmental conditions can it tolerate?
A7: Operating range: 0 °C to 60 °C; storage: −40 °C to +85 °C. The coated version enhances resistance to moisture, dust, and corrosion.

Q8: How is fault detection handled?
A8: The module supports diagnostics to detect short circuits, open loads, or channel faults and report them to the control system.

Q9: Can the module be replaced during operation (hot-swap)?
A9: Hot-swapping depends on system support. The module is modular, but safe replacement should follow system procedures to avoid signal loss.

Q10: What should I check when selecting this module?
A10: Verify channel count needed, load current per output, environmental conditions, whether coating protection is required, required isolation, and compatibility with the I/O termination modules and backplane.


Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501