• Bently Nevada 3300/12-01-20-01 Power Supply Module
  • Bently Nevada 3300/12-01-20-01 Power Supply Module
  • Bently Nevada 3300/12-01-20-01 Power Supply Module
  • Bently Nevada 3300/12-01-20-01 Power Supply Module
1. Product Overview — Bently Nevada 3300/12‑01‑20‑01 Introduction The 3300/12‑01‑20‑01 is a module in the 3300 series of rack/monitor modules, often used within the 3300 instrumentation rack to deliver ……
Bently Nevada 3300/12-01-20-01 Power Supply Module
  • Bently Nevada
  • 3300/12-01-20-01
  • Power Supply Module
  • USA
  • 127 mm × 25.4 mm × 178 mm
  • 0.6kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 193

Our advantage

Bently Nevada 3300/12-01-20-01 Power Supply Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Bently Nevada 3300/12-01-20-01 Power Supply Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Bently Nevada 3300/12-01-20-01 Power Supply Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Bently Nevada 3300/12-01-20-01 Power Supply Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


7. FAQs (Q / A)

Q1: What is the function of 3300/12‑01‑20‑01?
A1: It acts as a power / barrier / support module in a 3300 instrumentation rack, supplying regulated DC voltage and isolation for monitor modules.

Q2: What input AC voltages does it support?
A2: It typically supports 95–125 VAC or 190–250 VAC input, switchable.

Q3: What DC voltages does it provide to monitors / transducers?
A3: It delivers regulated outputs such as –24 VDC or –18 VDC, depending on configuration.

Q4: What is the module’s weight?
A4: About ~0.60 kg (600 grams).

Q5: What temperature range does it operate in?
A5: From –20°C to +70°C operational; storage –40°C to +85°C.

Q6: Does it include protective barriers?
A6: Yes, internal safety / isolation barriers are part of its design.

Q7: What ripple / noise performance is typical?
A7: Ripple and noise is minimal, often <1% or < ±50 mV peak.

Q8: Can it power multiple monitor modules?
A8: Yes — it is designed to supply current to multiple 3300 monitors and transducer chains.

Q9: Is it cooled by fan or convection?
A9: It uses natural convection cooling; no internal fan.

Q10: Does it support global deployment?
A10: Yes — switchable AC input and design variants allow use in many regions.