• Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor
  • Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor
  • Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor
  • Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor
Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor Product Overview The PR6423/10R‑010‑CN is an 8 mm non‑contact eddy‑current sensor engineered by Epro. It converts minute changes in the distance between t……
Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor
  • Epro
  • PR6423/10R‑010‑CN
  • 8 mm Eddy‑Current Sensor
  • Germany
  • 8mm
  • 0.1kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 305

Our advantage

Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Epro PR6423/10R‑010‑CN 8 mm Eddy‑Current Sensor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Frequently Asked Questions (FAQ)

Q1: What gap range does the PR6423/10R‑010‑CN cover?
A1: It offers a calibrated linear range of 0 to 2.0 mm, suitable for most medium‑clearance machinery shafts.

Q2: Which proximitor should be used with this probe?
A2: The probe is optimised for pairing with Epro CON 011 or CON 021 proximity sensor modules.

Q3: Is the sensor interchangeable with other PR6423 probes?
A3: Yes. All PR6423 variants share identical electrical characteristics; any probe can replace another after proper mechanical alignment.

Q4: Can the probe operate in hazardous areas?
A4: An ATEX II 1G Ex ia IIC T4 certified version is available on request for Zone 0/1 installations.

Q5: How is the probe installed?
A5: Thread the probe into a radial or axial port so that the tip faces the conductive target, then lock it in place using the supplied jam nut.

Q6: Does cable length influence calibration?
A6: Each probe is factory‑matched to its cable length; altering cable length without recalibration will affect sensitivity and linearity.

Q7: What shaft materials are compatible?
A7: Carbon steel, stainless steel and Inconel provide the specified calibration constants; non‑ferrous alloys may require custom calibration.

Q8: How often is recalibration required?
A8: With proper installation, recalibration is generally unnecessary; periodic verification during shutdowns suffices.

Q9: What environmental sealing does the probe offer?
A9: The probe head is hermetically welded and rated to IP68, ensuring ingress protection against oil and water immersion.

Q10: What is the maximum extension cable length?
A10: The PR6423 system supports up to 10 m of integral cable; longer runs require a high‑integrity armour and a calibrated CON 021 module.