• Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
Product Overview Model: Bently Nevada 3500/04 176449‑01+125680‑01 Brand & Series Brand: [Brand Name Hidden]Series: [Series Name Hidden] 1. Parameters Parameter Specification Model Number 3……
Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • Bently Nevada
  • 3500/04 176449-01+125680-01
  • Proximitor Monitor + Proximitor I/O Module with Internal Terminations
  • USA
  • 300 mm × 150 mm × 200 mm
  • 4.2kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 68

Our advantage

Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Bently Nevada 3500/04 176449-01+125680-01 Proximitor Monitor + Proximitor I/O Module with Internal Terminations

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


8. FAQ (Q & A)

Q1: What is the purpose of combining two model numbers (176449‑01 + 125680‑01)?
A1: It denotes the base module (176449‑01) plus an extension or option board (125680‑01) that adds enhanced I/O or communications capabilities.

Q2: Can this unit operate on 24 V DC only, or is 48 V supported?
A2: It is rated for 24 V DC nominal; 48 V is not supported and may damage internal circuitry unless explicitly ordered with a converter module.

Q3: How are firmware updates handled?
A3: Updates are applied via the RS‑485 port using a manufacturer‑provided firmware utility. The device must be taken offline and rebooted to complete the operation.

Q4: What self‑tests are included?
A4: The unit tests analog input ranges, relay activation logic, internal power health, memory integrity, and communication port function on every startup and periodically in‑service.

Q5: Is there a backup power or battery?
A5: No internal battery backup is included. If external power is lost, the device resets; for critical systems, external UPS or dual supply options are advised.

Q6: Can it log data onboard?
A6: It does not include onboard logging. Real‑time data must be captured by a connected PCM/SCADA or condition monitoring system.

Q7: How do I configure the analog output scaling?
A7: Scaling (e.g. 4–20 mA calibration) is set via a configuration tool over RS‑485; ranges and zero/span values can be tailored to sensor outputs.

Q8: What maintenance is recommended?
A8: Regular visual inspection of connectors, firmware updates, annual calibration of analog output, and functional test of relay contacts are recommended.

Q9: Is diagnostic firmware proprietary? Can I write my own?
A9: Diagnostic firmware is proprietary to the brand. Custom firmware is not supported and may void warranty or impair safety.

Q10: What happens when a critical fault occurs?
A10: The device opens relay circuits, drives fault LEDs, and reports the fault code via RS‑485. Analog outputs default to a safe output (e.g. 20 mA) or zero, depending on configuration.


Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501