Q1: What is the flow range of the NFAI141-S50?
A1: The NFAI141-S50 has a flow range from 0.03 to 10 m/s.
Q2: What is the accuracy of the NFAI141-S50?
A2: The NFAI141-S50 offers an accuracy of ±0.5% of full scale.
Q3: Can the NFAI141-S50 be used in corrosive environments?
A3: Yes, the NFAI141-S50 is made of stainless steel 316L, which offers excellent corrosion resistance, making it suitable for use in aggressive environments.
Q4: What industries use the NFAI141-S50?
A4: The NFAI141-S50 is used in industries like water treatment, oil and gas, chemicals, pharmaceuticals, and food and beverage.
Q5: Does the NFAI141-S50 support HART communication?
A5: Yes, the NFAI141-S50 supports HART communication, enabling integration with control systems for enhanced monitoring.
Q6: What is the power supply for the NFAI141-S50?
A6: The NFAI141-S50 operates with a 24 V DC power supply.
Q7: What is the ingress protection rating of the NFAI141-S50?
A7: The NFAI141-S50 is rated IP67, making it dustproof and resistant to water ingress.
Q8: Can the NFAI141-S50 be used outdoors?
A8: Yes, the NFAI141-S50 can be used outdoors due to its IP67 rating and robust construction.
Q9: What is the operating temperature range for the NFAI141-S50?
A9: The NFAI141-S50 operates in a temperature range from -25°C to +70°C.
Q10: What are the connection types for the NFAI141-S50?
A10: The NFAI141-S50 supports flanged connections (DN25 to DN300).